Free shipping above ₹10,000  ·  GST invoice on every order +91 99111 93212  ·  Mon–Sat, 9:30 to 18:30 IST

Single phase — 1 HP Siemens V20 AC Drive

Siemens V20 AC drive, single-phase input, 1 HP / 0.75 kW.

Phase
Single
Power
0.75 kW

Overview

This is a Siemens V20 variable frequency drive (model 6SL3210-5BB17-5UV1), rated 1 HP / 0.75 kW, taking a single-phase AC supply (200-240 V AC, 47-63 Hz) and outputting three-phase power to run a standard induction motor - a spindle motor, for instance - at variable speed. Rated input current is 10 A, output current 3.9 A - frame size A, air-cooled without a fan.

It takes a 150% overload for 60 seconds, covers an output frequency range of 0 to 550 Hz, and offers linear, quadratic and multi-point V/f control plus flux current control (FCC), set up from its own built-in keypad with connection and application macros or over an RS-485 port running USS or Modbus RTU.

At 0.75 kW this is the smallest drive in the range, suited to a light spindle rather than a heavier load. For more power on the same single-phase supply, the 2 HP, 3 HP and 4 HP models step up; where a three-phase supply is available, the three-phase-input V20 range (6SL3210-5BE series) starts at 4 HP.

The V20 is a genuine Siemens product, not a Tiny Controls design - it is supplied, not assembled or designed, in India.

Specifications

Single phase — 1 HP Siemens V20 AC Drive technical specifications
Phase Single
Power 0.75 kW
Input voltage 200 - 240 V AC
Frequency 47 - 63 Hz
Input current 10 A
Output current 3.9 A

Questions

What size motor or load does this suit?

Rated 1 HP / 0.75 kW output, 3.9 A output current — the smallest model in this single-phase range, suited to a light spindle rather than a heavy load.

Can it really run a three-phase motor from a single-phase wall supply?

Yes. It takes single-phase 200-240 V AC in (47-63 Hz) and outputs three-phase power to run a standard induction motor at variable speed.

What's the overload capacity?

150% overload for 60 seconds.

How is it programmed — keypad, or a PC?

Either: the built-in keypad (with connection and application macros), or remotely over an RS-485 port running USS or Modbus RTU.

What if I need more power, or have a three-phase supply available?

On the same single-phase supply, the 2 HP, 3 HP and 4 HP models in this range step up. Where a three-phase supply is available instead, the three-phase-input V20 range (6SL3210-5BE series) starts at 4 HP.