Single phase — 4 HP Siemens V20 AC Drive

Siemens V20 AC drive, single-phase input, 4 HP / 3.0 kW.

Phase
Single
Power
3.0 kW

Overview

This is a Siemens V20 variable frequency drive (model 6SL3210-5BB23-0UV0), rated 4 HP / 3.0 kW, taking a single-phase AC supply (200-240 V AC, 47-63 Hz) and outputting three-phase power to run a standard induction motor at variable speed. Rated input current is 32 A, output current 13.6 A - frame size C, cooled by a single fan.

It takes a 150% overload for 60 seconds, covers an output frequency range of 0 to 550 Hz, and offers linear, quadratic and multi-point V/f control plus flux current control (FCC), set up from its own built-in keypad with connection and application macros or over an RS-485 port running USS or Modbus RTU.

This is the ceiling of the single-phase-input side of the V20 range here - a three-phase-input version at the same 4 HP / 3.0 kW rating (6SL3210-5BE23-0UV0) also exists, drawing less current per phase on a three-phase supply instead. Beyond 3.0 kW, only the three-phase-input drives go further, up to 10 HP. Below it, the 1 HP, 2 HP and 3 HP single-phase models cover progressively lighter motors.

The V20 is a genuine Siemens product, not a Tiny Controls design - it is supplied, not assembled or designed, in India.

Specifications

Single phase — 4 HP Siemens V20 AC Drive technical specifications
Phase Single
Power 3.0 kW
Input voltage 200 - 240 V AC
Frequency 47 - 63 Hz
Input current 32 A
Output current 13.6 A

Questions

What size motor or load does this suit?

Rated 4 HP / 3.0 kW output, 13.6 A output current — the ceiling of the single-phase-input side of this V20 range.

Can it really run a three-phase motor from a single-phase wall supply?

Yes. It takes single-phase 200-240 V AC in (47-63 Hz) and outputs three-phase power to run a standard induction motor at variable speed.

Does it include a braking resistor?

No. For frame sizes A-C (this model included), a braking resistor is an external, separately-fitted option via the dynamic braking module — not built in. The drive's own DC-link overvoltage trip (fault F2) protects it if one isn't fitted, but a sustained regenerative load needs the resistor to avoid tripping.

Is there a three-phase version at the same power, or should I go bigger?

A three-phase-input version at the same 4 HP / 3.0 kW rating (6SL3210-5BE23-0UV0) also exists, drawing less current per phase on a three-phase supply. Beyond 3.0 kW, only the three-phase-input drives go further, up to 10 HP. Below it, the 1 HP, 2 HP and 3 HP single-phase models cover progressively lighter motors.